* 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/lrg/voltage-2.6: (32 commits) regulator: twl4030 VAUX3 supports 3.0V regulator: Support disabling of unused regulators by machines regulator: Don't increment use_count for boot_on regulators twl4030-regulator: expose VPLL2 regulator: refcount fixes regulator: Don't warn if we failed to get a regulator regulator: Allow boot_on regulators to be disabled by clients regulator: Implement list_voltage for WM835x LDOs and DCDCs twl4030-regulator: list more VAUX4 voltages regulator: Don't warn on omitted voltage constraints regulator: Implement list_voltage() for WM8400 DCDCs and LDOs MMC: regulator utilities regulator: twl4030 voltage enumeration (v2) regulator: twl4030 regulators regulator: get_status() grows kerneldoc regulator: enumerate voltages (v2) regulator: Fix get_mode() for WM835x DCDCs regulator: Allow regulators to set the initial operating mode regulator: Suggest use of datasheet supply or pin names for consumers regulator: email - update email address and regulator webpage. ...
This commit is contained in:
@@ -4,8 +4,8 @@ KernelVersion: 2.6.26
|
||||
Contact: Liam Girdwood <lrg@slimlogic.co.uk>
|
||||
Description:
|
||||
Some regulator directories will contain a field called
|
||||
state. This reports the regulator enable status, for
|
||||
regulators which can report that value.
|
||||
state. This reports the regulator enable control, for
|
||||
regulators which can report that input value.
|
||||
|
||||
This will be one of the following strings:
|
||||
|
||||
@@ -14,16 +14,54 @@ Description:
|
||||
'unknown'
|
||||
|
||||
'enabled' means the regulator output is ON and is supplying
|
||||
power to the system.
|
||||
power to the system (assuming no error prevents it).
|
||||
|
||||
'disabled' means the regulator output is OFF and is not
|
||||
supplying power to the system..
|
||||
supplying power to the system (unless some non-Linux
|
||||
control has enabled it).
|
||||
|
||||
'unknown' means software cannot determine the state, or
|
||||
the reported state is invalid.
|
||||
|
||||
NOTE: this field can be used in conjunction with microvolts
|
||||
and microamps to determine regulator output levels.
|
||||
or microamps to determine configured regulator output levels.
|
||||
|
||||
|
||||
What: /sys/class/regulator/.../status
|
||||
Description:
|
||||
Some regulator directories will contain a field called
|
||||
"status". This reports the current regulator status, for
|
||||
regulators which can report that output value.
|
||||
|
||||
This will be one of the following strings:
|
||||
|
||||
off
|
||||
on
|
||||
error
|
||||
fast
|
||||
normal
|
||||
idle
|
||||
standby
|
||||
|
||||
"off" means the regulator is not supplying power to the
|
||||
system.
|
||||
|
||||
"on" means the regulator is supplying power to the system,
|
||||
and the regulator can't report a detailed operation mode.
|
||||
|
||||
"error" indicates an out-of-regulation status such as being
|
||||
disabled due to thermal shutdown, or voltage being unstable
|
||||
because of problems with the input power supply.
|
||||
|
||||
"fast", "normal", "idle", and "standby" are all detailed
|
||||
regulator operation modes (described elsewhere). They
|
||||
imply "on", but provide more detail.
|
||||
|
||||
Note that regulator status is a function of many inputs,
|
||||
not limited to control inputs from Linux. For example,
|
||||
the actual load presented may trigger "error" status; or
|
||||
a regulator may be enabled by another user, even though
|
||||
Linux did not enable it.
|
||||
|
||||
|
||||
What: /sys/class/regulator/.../type
|
||||
@@ -58,7 +96,7 @@ Description:
|
||||
Some regulator directories will contain a field called
|
||||
microvolts. This holds the regulator output voltage setting
|
||||
measured in microvolts (i.e. E-6 Volts), for regulators
|
||||
which can report that voltage.
|
||||
which can report the control input for voltage.
|
||||
|
||||
NOTE: This value should not be used to determine the regulator
|
||||
output voltage level as this value is the same regardless of
|
||||
@@ -73,7 +111,7 @@ Description:
|
||||
Some regulator directories will contain a field called
|
||||
microamps. This holds the regulator output current limit
|
||||
setting measured in microamps (i.e. E-6 Amps), for regulators
|
||||
which can report that current.
|
||||
which can report the control input for a current limit.
|
||||
|
||||
NOTE: This value should not be used to determine the regulator
|
||||
output current level as this value is the same regardless of
|
||||
@@ -87,7 +125,7 @@ Contact: Liam Girdwood <lrg@slimlogic.co.uk>
|
||||
Description:
|
||||
Some regulator directories will contain a field called
|
||||
opmode. This holds the current regulator operating mode,
|
||||
for regulators which can report it.
|
||||
for regulators which can report that control input value.
|
||||
|
||||
The opmode value can be one of the following strings:
|
||||
|
||||
@@ -101,7 +139,8 @@ Description:
|
||||
|
||||
NOTE: This value should not be used to determine the regulator
|
||||
output operating mode as this value is the same regardless of
|
||||
whether the regulator is enabled or disabled.
|
||||
whether the regulator is enabled or disabled. A "status"
|
||||
attribute may be available to determine the actual mode.
|
||||
|
||||
|
||||
What: /sys/class/regulator/.../min_microvolts
|
||||
|