sfc: Use a single blink implementation
Only some PHYs have firmware support for a LED blink mode, so we currently blink the others in a timer function. Since all PHYs have simple on and off modes, we don't gain anything by using multiple blink implementations. Also, since we have a process context there is no need to use a timer. Signed-off-by: Ben Hutchings <bhutchings@solarflare.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
committed by
David S. Miller
parent
dcf477b2d2
commit
398468ed1b
@@ -1890,7 +1890,9 @@ int efx_port_dummy_op_int(struct efx_nic *efx)
|
||||
return 0;
|
||||
}
|
||||
void efx_port_dummy_op_void(struct efx_nic *efx) {}
|
||||
void efx_port_dummy_op_blink(struct efx_nic *efx, bool blink) {}
|
||||
void efx_port_dummy_op_set_id_led(struct efx_nic *efx, enum efx_led_mode mode)
|
||||
{
|
||||
}
|
||||
|
||||
static struct efx_mac_operations efx_dummy_mac_operations = {
|
||||
.reconfigure = efx_port_dummy_op_void,
|
||||
@@ -1909,9 +1911,8 @@ static struct efx_phy_operations efx_dummy_phy_operations = {
|
||||
static struct efx_board efx_dummy_board_info = {
|
||||
.init = efx_port_dummy_op_int,
|
||||
.init_leds = efx_port_dummy_op_void,
|
||||
.set_id_led = efx_port_dummy_op_blink,
|
||||
.set_id_led = efx_port_dummy_op_set_id_led,
|
||||
.monitor = efx_port_dummy_op_int,
|
||||
.blink = efx_port_dummy_op_blink,
|
||||
.fini = efx_port_dummy_op_void,
|
||||
};
|
||||
|
||||
|