USB: cdc-acm: remove unused drain-delay code
The drain-delay code is no longer used, so remove it. Signed-off-by: Johan Hovold <jhovold@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
3a42610812
commit
6fb6b88464
@@ -112,7 +112,6 @@ struct acm {
|
||||
struct mutex mutex;
|
||||
struct usb_cdc_line_coding line; /* bits, stop, parity */
|
||||
struct work_struct work; /* work queue entry for line discipline waking up */
|
||||
wait_queue_head_t drain_wait; /* close processing */
|
||||
struct tasklet_struct urb_task; /* rx processing */
|
||||
spinlock_t throttle_lock; /* synchronize throtteling and read callback */
|
||||
unsigned int ctrlin; /* input control lines (DCD, DSR, RI, break, overruns) */
|
||||
|