ACPI: update thermal temperature
Fix the problem that thermal_get_temp returns the cached value, which causes the temperature in generic thermal never updates. Signed-off-by: Zhang Rui <rui.zhang@intel.com> Acked-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Len Brown <len.brown@intel.com>
This commit is contained in:
@@ -884,10 +884,15 @@ static void acpi_thermal_check(void *data)
|
|||||||
static int thermal_get_temp(struct thermal_zone_device *thermal, char *buf)
|
static int thermal_get_temp(struct thermal_zone_device *thermal, char *buf)
|
||||||
{
|
{
|
||||||
struct acpi_thermal *tz = thermal->devdata;
|
struct acpi_thermal *tz = thermal->devdata;
|
||||||
|
int result;
|
||||||
|
|
||||||
if (!tz)
|
if (!tz)
|
||||||
return -EINVAL;
|
return -EINVAL;
|
||||||
|
|
||||||
|
result = acpi_thermal_get_temperature(tz);
|
||||||
|
if (result)
|
||||||
|
return result;
|
||||||
|
|
||||||
return sprintf(buf, "%ld\n", KELVIN_TO_MILLICELSIUS(tz->temperature));
|
return sprintf(buf, "%ld\n", KELVIN_TO_MILLICELSIUS(tz->temperature));
|
||||||
}
|
}
|
||||||
|
|
||||||
|