s390/time: fix get_tod_clock_ext inline assembly
The get_tod_clock_ext inline assembly does not specify its output operands correctly. This can cause incorrect code to be generated. Cc: stable@vger.kernel.org # 3.12 Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
@@ -71,9 +71,11 @@ static inline void local_tick_enable(unsigned long long comp)
|
|||||||
|
|
||||||
typedef unsigned long long cycles_t;
|
typedef unsigned long long cycles_t;
|
||||||
|
|
||||||
static inline void get_tod_clock_ext(char *clk)
|
static inline void get_tod_clock_ext(char clk[16])
|
||||||
{
|
{
|
||||||
asm volatile("stcke %0" : "=Q" (*clk) : : "cc");
|
typedef struct { char _[sizeof(clk)]; } addrtype;
|
||||||
|
|
||||||
|
asm volatile("stcke %0" : "=Q" (*(addrtype *) clk) : : "cc");
|
||||||
}
|
}
|
||||||
|
|
||||||
static inline unsigned long long get_tod_clock(void)
|
static inline unsigned long long get_tod_clock(void)
|
||||||
|
Reference in New Issue