mac80211: Fix dynamic power save for scanning.

Not only ps_sdata but also IEEE80211_CONF_PS is to be considered
before restoring PS in scan_ps_disable(). For instance, when ps_sdata
is set but CONF_PS is not set just because the dynamic timer is still
running, a sw scan leads to setting of CONF_PS in scan_ps_disable
instead of restarting the dynamic PS timer.
Also for the above case, a null data frame is to be sent after
returning to operating channel which was not happening with the
current implementation. This patch fixes this too.

Signed-off-by: Vivek Natarajan <vnatarajan@atheros.com>
Reviewed-by: Kalle Valo <kalle.valo@nokia.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Vivek Natarajan
2009-11-30 16:50:53 +05:30
committed by John W. Linville
parent bc83b68192
commit 7c3f4bbedc
2 changed files with 17 additions and 4 deletions

View File

@@ -746,6 +746,7 @@ struct ieee80211_local {
unsigned int wmm_acm; /* bit field of ACM bits (BIT(802.1D tag)) */
bool pspolling;
bool scan_ps_enabled;
/*
* PS can only be enabled when we have exactly one managed
* interface (and monitors) in PS, this then points there.