mtd: Move fdt partition documentation to a seperate file
Partitions are described in the same way for all mtd devices when using devicetree, move the documentation to a separate file and add references to it. Signed-off-by: Jamie Lentin <jm@lentin.co.uk> Acked-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Jason Cooper <jason@lakedaemon.net> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
This commit is contained in:
committed by
Grant Likely
parent
735e941caa
commit
83619ea08e
@@ -4,5 +4,5 @@ Required properties:
|
|||||||
- compatible : must be "arm,versatile-flash";
|
- compatible : must be "arm,versatile-flash";
|
||||||
- bank-width : width in bytes of flash interface.
|
- bank-width : width in bytes of flash interface.
|
||||||
|
|
||||||
Optional properties:
|
The device tree may optionally contain sub-nodes describing partitions of the
|
||||||
- Subnode partition map from mtd flash binding
|
address space. See partition.txt for more detail.
|
||||||
|
@@ -3,6 +3,9 @@
|
|||||||
Required properties:
|
Required properties:
|
||||||
- compatible : "atmel,<model>", "atmel,<series>", "atmel,dataflash".
|
- compatible : "atmel,<model>", "atmel,<series>", "atmel,dataflash".
|
||||||
|
|
||||||
|
The device tree may optionally contain sub-nodes describing partitions of the
|
||||||
|
address space. See partition.txt for more detail.
|
||||||
|
|
||||||
Example:
|
Example:
|
||||||
|
|
||||||
flash@1 {
|
flash@1 {
|
||||||
|
@@ -19,6 +19,10 @@ Optional properties:
|
|||||||
read registers (tR). Required if property "gpios" is not used
|
read registers (tR). Required if property "gpios" is not used
|
||||||
(R/B# pins not connected).
|
(R/B# pins not connected).
|
||||||
|
|
||||||
|
Each flash chip described may optionally contain additional sub-nodes
|
||||||
|
describing partitions of the address space. See partition.txt for more
|
||||||
|
detail.
|
||||||
|
|
||||||
Examples:
|
Examples:
|
||||||
|
|
||||||
upm@1,0 {
|
upm@1,0 {
|
||||||
|
@@ -25,6 +25,9 @@ Optional properties:
|
|||||||
GPIO state and before and after command byte writes, this register will be
|
GPIO state and before and after command byte writes, this register will be
|
||||||
read to ensure that the GPIO accesses have completed.
|
read to ensure that the GPIO accesses have completed.
|
||||||
|
|
||||||
|
The device tree may optionally contain sub-nodes describing partitions of the
|
||||||
|
address space. See partition.txt for more detail.
|
||||||
|
|
||||||
Examples:
|
Examples:
|
||||||
|
|
||||||
gpio-nand@1,0 {
|
gpio-nand@1,0 {
|
||||||
|
@@ -23,27 +23,8 @@ are defined:
|
|||||||
- vendor-id : Contains the flash chip's vendor id (1 byte).
|
- vendor-id : Contains the flash chip's vendor id (1 byte).
|
||||||
- device-id : Contains the flash chip's device id (1 byte).
|
- device-id : Contains the flash chip's device id (1 byte).
|
||||||
|
|
||||||
In addition to the information on the mtd bank itself, the
|
The device tree may optionally contain sub-nodes describing partitions of the
|
||||||
device tree may optionally contain additional information
|
address space. See partition.txt for more detail.
|
||||||
describing partitions of the address space. This can be
|
|
||||||
used on platforms which have strong conventions about which
|
|
||||||
portions of a flash are used for what purposes, but which don't
|
|
||||||
use an on-flash partition table such as RedBoot.
|
|
||||||
|
|
||||||
Each partition is represented as a sub-node of the mtd device.
|
|
||||||
Each node's name represents the name of the corresponding
|
|
||||||
partition of the mtd device.
|
|
||||||
|
|
||||||
Flash partitions
|
|
||||||
- reg : The partition's offset and size within the mtd bank.
|
|
||||||
- label : (optional) The label / name for this partition.
|
|
||||||
If omitted, the label is taken from the node name (excluding
|
|
||||||
the unit address).
|
|
||||||
- read-only : (optional) This parameter, if present, is a hint to
|
|
||||||
Linux that this partition should only be mounted
|
|
||||||
read-only. This is usually used for flash partitions
|
|
||||||
containing early-boot firmware images or data which should not
|
|
||||||
be clobbered.
|
|
||||||
|
|
||||||
Example:
|
Example:
|
||||||
|
|
||||||
|
38
Documentation/devicetree/bindings/mtd/partition.txt
Normal file
38
Documentation/devicetree/bindings/mtd/partition.txt
Normal file
@@ -0,0 +1,38 @@
|
|||||||
|
Representing flash partitions in devicetree
|
||||||
|
|
||||||
|
Partitions can be represented by sub-nodes of an mtd device. This can be used
|
||||||
|
on platforms which have strong conventions about which portions of a flash are
|
||||||
|
used for what purposes, but which don't use an on-flash partition table such
|
||||||
|
as RedBoot.
|
||||||
|
|
||||||
|
#address-cells & #size-cells must both be present in the mtd device and be
|
||||||
|
equal to 1.
|
||||||
|
|
||||||
|
Required properties:
|
||||||
|
- reg : The partition's offset and size within the mtd bank.
|
||||||
|
|
||||||
|
Optional properties:
|
||||||
|
- label : The label / name for this partition. If omitted, the label is taken
|
||||||
|
from the node name (excluding the unit address).
|
||||||
|
- read-only : This parameter, if present, is a hint to Linux that this
|
||||||
|
partition should only be mounted read-only. This is usually used for flash
|
||||||
|
partitions containing early-boot firmware images or data which should not be
|
||||||
|
clobbered.
|
||||||
|
|
||||||
|
Examples:
|
||||||
|
|
||||||
|
|
||||||
|
flash@0 {
|
||||||
|
#address-cells = <1>;
|
||||||
|
#size-cells = <1>;
|
||||||
|
|
||||||
|
partition@0 {
|
||||||
|
label = "u-boot";
|
||||||
|
reg = <0x0000000 0x100000>;
|
||||||
|
read-only;
|
||||||
|
};
|
||||||
|
|
||||||
|
uimage@100000 {
|
||||||
|
reg = <0x0100000 0x200000>;
|
||||||
|
};
|
||||||
|
];
|
Reference in New Issue