[POWERPC] Generic check_legacy_ioport
check_legacy_ioport makes only sense on PREP, CHRP and pSeries. They may have an isa node with PS/2, parport, floppy and serial ports. Remove the check_legacy_ioport call from ppc_md, it's not needed anymore. Hardware capabilities come from the device-tree. Signed-off-by: Olaf Hering <olaf@aepfle.de> Signed-off-by: Paul Mackerras <paulus@samba.org>
This commit is contained in:
committed by
Paul Mackerras
parent
8d2169e8d6
commit
8d8a0241eb
@ -190,15 +190,6 @@ static int __init cell_probe(void)
|
||||
return 1;
|
||||
}
|
||||
|
||||
/*
|
||||
* Cell has no legacy IO; anything calling this function has to
|
||||
* fail or bad things will happen
|
||||
*/
|
||||
static int cell_check_legacy_ioport(unsigned int baseport)
|
||||
{
|
||||
return -ENODEV;
|
||||
}
|
||||
|
||||
define_machine(cell) {
|
||||
.name = "Cell",
|
||||
.probe = cell_probe,
|
||||
@ -211,7 +202,6 @@ define_machine(cell) {
|
||||
.get_rtc_time = rtas_get_rtc_time,
|
||||
.set_rtc_time = rtas_set_rtc_time,
|
||||
.calibrate_decr = generic_calibrate_decr,
|
||||
.check_legacy_ioport = cell_check_legacy_ioport,
|
||||
.progress = cell_progress,
|
||||
.init_IRQ = cell_init_irq,
|
||||
.pci_setup_phb = rtas_setup_phb,
|
||||
|
Reference in New Issue