mfd: db8500-prcmu: Supply the pdata_size attribute for db8500-thermal
The MFD subsystem requires drivers to state the size of any platform data passed, or it will fail to assign it to the device. This will culminate in a NULL platform_data attribute and normally a failure to probe() or a kernel Oops. Acked-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
This commit is contained in:
@@ -3095,6 +3095,7 @@ static struct mfd_cell db8500_prcmu_devs[] = {
|
|||||||
.num_resources = ARRAY_SIZE(db8500_thsens_resources),
|
.num_resources = ARRAY_SIZE(db8500_thsens_resources),
|
||||||
.resources = db8500_thsens_resources,
|
.resources = db8500_thsens_resources,
|
||||||
.platform_data = &db8500_thsens_data,
|
.platform_data = &db8500_thsens_data,
|
||||||
|
.pdata_size = sizeof(db8500_thsens_data),
|
||||||
},
|
},
|
||||||
};
|
};
|
||||||
|
|
||||||
|
Reference in New Issue
Block a user