hwmon: (tmp421) Fix temperature conversions
The low bits of temperature registers are status bits, they must be masked out before converting the register values to temperatures. Signed-off-by: Jean Delvare <khali@linux-fr.org> Tested-by: Andre Prendel <andre.prendel@gmx.de> Cc: stable@kernel.org
This commit is contained in:
@@ -80,14 +80,16 @@ struct tmp421_data {
|
|||||||
|
|
||||||
static int temp_from_s16(s16 reg)
|
static int temp_from_s16(s16 reg)
|
||||||
{
|
{
|
||||||
int temp = reg;
|
/* Mask out status bits */
|
||||||
|
int temp = reg & ~0xf;
|
||||||
|
|
||||||
return (temp * 1000 + 128) / 256;
|
return (temp * 1000 + 128) / 256;
|
||||||
}
|
}
|
||||||
|
|
||||||
static int temp_from_u16(u16 reg)
|
static int temp_from_u16(u16 reg)
|
||||||
{
|
{
|
||||||
int temp = reg;
|
/* Mask out status bits */
|
||||||
|
int temp = reg & ~0xf;
|
||||||
|
|
||||||
/* Add offset for extended temperature range. */
|
/* Add offset for extended temperature range. */
|
||||||
temp -= 64 * 256;
|
temp -= 64 * 256;
|
||||||
|