[POWERPC] pci_32.c: Switch to ref counting PCI API
pci_find_slot isn't hot-plug safe. Move this code to the pci hotplug safe equivalent and hold a refcount properly while doing make_one_node_map. Signed-off-by: Alan Cox <alan@redhat.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
This commit is contained in:
@@ -656,10 +656,13 @@ make_one_node_map(struct device_node* node, u8 pci_bus)
|
|||||||
reg = of_get_property(node, "reg", NULL);
|
reg = of_get_property(node, "reg", NULL);
|
||||||
if (!reg)
|
if (!reg)
|
||||||
continue;
|
continue;
|
||||||
dev = pci_find_slot(pci_bus, ((reg[0] >> 8) & 0xff));
|
dev = pci_get_bus_and_slot(pci_bus, ((reg[0] >> 8) & 0xff));
|
||||||
if (!dev || !dev->subordinate)
|
if (!dev || !dev->subordinate) {
|
||||||
|
pci_dev_put(dev);
|
||||||
continue;
|
continue;
|
||||||
|
}
|
||||||
make_one_node_map(node, dev->subordinate->number);
|
make_one_node_map(node, dev->subordinate->number);
|
||||||
|
pci_dev_put(dev);
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
Reference in New Issue