hwmon: add support for THMC50 and ADM1022
This patch adds support for THMC50 and ADM1022 hardware monitoring chips. Signed-off-by: Krzysztof Helt <krzysztof.h1@wp.pl> Acked-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
This commit is contained in:
committed by
Mark M. Hoffman
parent
80ba80a9bf
commit
add77c64ca
74
Documentation/hwmon/thmc50
Normal file
74
Documentation/hwmon/thmc50
Normal file
@@ -0,0 +1,74 @@
|
||||
Kernel driver thmc50
|
||||
=====================
|
||||
|
||||
Supported chips:
|
||||
* Analog Devices ADM1022
|
||||
Prefix: 'adm1022'
|
||||
Addresses scanned: I2C 0x2c - 0x2e
|
||||
Datasheet: http://www.analog.com/en/prod/0,2877,ADM1022,00.html
|
||||
* Texas Instruments THMC50
|
||||
Prefix: 'thmc50'
|
||||
Addresses scanned: I2C 0x2c - 0x2e
|
||||
Datasheet: http://focus.ti.com/docs/prod/folders/print/thmc50.html
|
||||
|
||||
Author: Krzysztof Helt <krzysztof.h1@wp.pl>
|
||||
|
||||
This driver was derived from the 2.4 kernel thmc50.c source file.
|
||||
|
||||
Credits:
|
||||
thmc50.c (2.4 kernel):
|
||||
Frodo Looijaard <frodol@dds.nl>
|
||||
Philip Edelbrock <phil@netroedge.com>
|
||||
|
||||
Module Parameters
|
||||
-----------------
|
||||
|
||||
* adm1022_temp3: short array
|
||||
List of adapter,address pairs to force chips into ADM1022 mode with
|
||||
second remote temperature. This does not work for original THMC50 chips.
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
The THMC50 implements: an internal temperature sensor, support for an
|
||||
external diode-type temperature sensor (compatible w/ the diode sensor inside
|
||||
many processors), and a controllable fan/analog_out DAC. For the temperature
|
||||
sensors, limits can be set through the appropriate Overtemperature Shutdown
|
||||
register and Hysteresis register. Each value can be set and read to half-degree
|
||||
accuracy. An alarm is issued (usually to a connected LM78) when the
|
||||
temperature gets higher then the Overtemperature Shutdown value; it stays on
|
||||
until the temperature falls below the Hysteresis value. All temperatures are in
|
||||
degrees Celsius, and are guaranteed within a range of -55 to +125 degrees.
|
||||
|
||||
The THMC50 only updates its values each 1.5 seconds; reading it more often
|
||||
will do no harm, but will return 'old' values.
|
||||
|
||||
The THMC50 is usually used in combination with LM78-like chips, to measure
|
||||
the temperature of the processor(s).
|
||||
|
||||
The ADM1022 works the same as THMC50 but it is faster (5 Hz instead of
|
||||
1 Hz for THMC50). It can be also put in a new mode to handle additional
|
||||
remote temperature sensor. The driver use the mode set by BIOS by default.
|
||||
|
||||
In case the BIOS is broken and the mode is set incorrectly, you can force
|
||||
the mode with additional remote temperature with adm1022_temp3 parameter.
|
||||
A typical symptom of wrong setting is a fan forced to full speed.
|
||||
|
||||
Driver Features
|
||||
---------------
|
||||
|
||||
The driver provides up to three temperatures:
|
||||
|
||||
temp1 -- internal
|
||||
temp2 -- remote
|
||||
temp3 -- 2nd remote only for ADM1022
|
||||
|
||||
pwm1 -- fan speed (0 = stop, 255 = full)
|
||||
pwm1_mode -- always 0 (DC mode)
|
||||
|
||||
The value of 0 for pwm1 also forces FAN_OFF signal from the chip,
|
||||
so it stops fans even if the value 0 into the ANALOG_OUT register does not.
|
||||
|
||||
The driver was tested on Compaq AP550 with two ADM1022 chips (one works
|
||||
in the temp3 mode), five temperature readings and two fans.
|
||||
|