[PATCH] md: document sysfs usage of md, and make a couple of small refinements
Document in Documentation/md.txt the files that now appear in sysfs, and make a couple of small refinements to exactly when 'level' and 'raid_disks' are empty, to make it match the documentation. Signed-off-by: Neil Brown <neilb@suse.de> Acked-by: Greg Kroah-Hartman <gregkh@suse.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
This commit is contained in:
committed by
Linus Torvalds
parent
7eec314d75
commit
bb636547b0
@@ -116,3 +116,122 @@ and it's role in the array.
|
|||||||
|
|
||||||
Once started with RUN_ARRAY, uninitialized spares can be added with
|
Once started with RUN_ARRAY, uninitialized spares can be added with
|
||||||
HOT_ADD_DISK.
|
HOT_ADD_DISK.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
MD devices in sysfs
|
||||||
|
-------------------
|
||||||
|
md devices appear in sysfs (/sys) as regular block devices,
|
||||||
|
e.g.
|
||||||
|
/sys/block/md0
|
||||||
|
|
||||||
|
Each 'md' device will contain a subdirectory called 'md' which
|
||||||
|
contains further md-specific information about the device.
|
||||||
|
|
||||||
|
All md devices contain:
|
||||||
|
level
|
||||||
|
a text file indicating the 'raid level'. This may be a standard
|
||||||
|
numerical level prefixed by "RAID-" - e.g. "RAID-5", or some
|
||||||
|
other name such as "linear" or "multipath".
|
||||||
|
If no raid level has been set yet (array is still being
|
||||||
|
assembled), this file will be empty.
|
||||||
|
|
||||||
|
raid_disks
|
||||||
|
a text file with a simple number indicating the number of devices
|
||||||
|
in a fully functional array. If this is not yet known, the file
|
||||||
|
will be empty. If an array is being resized (not currently
|
||||||
|
possible) this will contain the larger of the old and new sizes.
|
||||||
|
|
||||||
|
As component devices are added to an md array, they appear in the 'md'
|
||||||
|
directory as new directories named
|
||||||
|
dev-XXX
|
||||||
|
where XXX is a name that the kernel knows for the device, e.g. hdb1.
|
||||||
|
Each directory contains:
|
||||||
|
|
||||||
|
block
|
||||||
|
a symlink to the block device in /sys/block, e.g.
|
||||||
|
/sys/block/md0/md/dev-hdb1/block -> ../../../../block/hdb/hdb1
|
||||||
|
|
||||||
|
super
|
||||||
|
A file containing an image of the superblock read from, or
|
||||||
|
written to, that device.
|
||||||
|
|
||||||
|
state
|
||||||
|
A file recording the current state of the device in the array
|
||||||
|
which can be a comma separated list of
|
||||||
|
faulty - device has been kicked from active use due to
|
||||||
|
a detected fault
|
||||||
|
in_sync - device is a fully in-sync member of the array
|
||||||
|
spare - device is working, but not a full member.
|
||||||
|
This includes spares that are in the process
|
||||||
|
of being recoverred to
|
||||||
|
This list make grow in future.
|
||||||
|
|
||||||
|
|
||||||
|
An active md device will also contain and entry for each active device
|
||||||
|
in the array. These are named
|
||||||
|
|
||||||
|
rdNN
|
||||||
|
|
||||||
|
where 'NN' is the possition in the array, starting from 0.
|
||||||
|
So for a 3 drive array there will be rd0, rd1, rd2.
|
||||||
|
These are symbolic links to the appropriate 'dev-XXX' entry.
|
||||||
|
Thus, for example,
|
||||||
|
cat /sys/block/md*/md/rd*/state
|
||||||
|
will show 'in_sync' on every line.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Active md devices for levels that support data redundancy (1,4,5,6)
|
||||||
|
also have
|
||||||
|
|
||||||
|
sync_action
|
||||||
|
a text file that can be used to monitor and control the rebuild
|
||||||
|
process. It contains one word which can be one of:
|
||||||
|
resync - redundancy is being recalculated after unclean
|
||||||
|
shutdown or creation
|
||||||
|
recover - a hot spare is being built to replace a
|
||||||
|
failed/missing device
|
||||||
|
idle - nothing is happening
|
||||||
|
check - A full check of redundancy was requested and is
|
||||||
|
happening. This reads all block and checks
|
||||||
|
them. A repair may also happen for some raid
|
||||||
|
levels.
|
||||||
|
repair - A full check and repair is happening. This is
|
||||||
|
similar to 'resync', but was requested by the
|
||||||
|
user, and the write-intent bitmap is NOT used to
|
||||||
|
optimise the process.
|
||||||
|
|
||||||
|
This file is writable, and each of the strings that could be
|
||||||
|
read are meaningful for writing.
|
||||||
|
|
||||||
|
'idle' will stop an active resync/recovery etc. There is no
|
||||||
|
guarantee that another resync/recovery may not be automatically
|
||||||
|
started again, though some event will be needed to trigger
|
||||||
|
this.
|
||||||
|
'resync' or 'recovery' can be used to restart the
|
||||||
|
corresponding operation if it was stopped with 'idle'.
|
||||||
|
'check' and 'repair' will start the appropriate process
|
||||||
|
providing the current state is 'idle'.
|
||||||
|
|
||||||
|
mismatch_count
|
||||||
|
When performing 'check' and 'repair', and possibly when
|
||||||
|
performing 'resync', md will count the number of errors that are
|
||||||
|
found. The count in 'mismatch_cnt' is the number of sectors
|
||||||
|
that were re-written, or (for 'check') would have been
|
||||||
|
re-written. As most raid levels work in units of pages rather
|
||||||
|
than sectors, this my be larger than the number of actual errors
|
||||||
|
by a factor of the number of sectors in a page.
|
||||||
|
|
||||||
|
Each active md device may also have attributes specific to the
|
||||||
|
personality module that manages it.
|
||||||
|
These are specific to the implementation of the module and could
|
||||||
|
change substantially if the implementation changes.
|
||||||
|
|
||||||
|
These currently include
|
||||||
|
|
||||||
|
stripe_cache_size (currently raid5 only)
|
||||||
|
number of entries in the stripe cache. This is writable, but
|
||||||
|
there are upper and lower limits (32768, 16). Default is 128.
|
||||||
|
strip_cache_active (currently raid5 only)
|
||||||
|
number of active entries in the stripe cache
|
||||||
|
@@ -1727,7 +1727,7 @@ static ssize_t
|
|||||||
level_show(mddev_t *mddev, char *page)
|
level_show(mddev_t *mddev, char *page)
|
||||||
{
|
{
|
||||||
mdk_personality_t *p = mddev->pers;
|
mdk_personality_t *p = mddev->pers;
|
||||||
if (p == NULL)
|
if (p == NULL && mddev->raid_disks == 0)
|
||||||
return 0;
|
return 0;
|
||||||
if (mddev->level >= 0)
|
if (mddev->level >= 0)
|
||||||
return sprintf(page, "RAID-%d\n", mddev->level);
|
return sprintf(page, "RAID-%d\n", mddev->level);
|
||||||
@@ -1740,6 +1740,8 @@ static struct md_sysfs_entry md_level = __ATTR_RO(level);
|
|||||||
static ssize_t
|
static ssize_t
|
||||||
raid_disks_show(mddev_t *mddev, char *page)
|
raid_disks_show(mddev_t *mddev, char *page)
|
||||||
{
|
{
|
||||||
|
if (mddev->raid_disks == 0)
|
||||||
|
return 0;
|
||||||
return sprintf(page, "%d\n", mddev->raid_disks);
|
return sprintf(page, "%d\n", mddev->raid_disks);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
Reference in New Issue