net: Refactor full duplex flow control resolution

These 4 drivers have identical full duplex flow control resolution
functions.  This patch changes them all to use one common function.

The function in question decides whether a device should enable TX and
RX flow control in a standard way (IEEE 802.3-2005 table 28B-3), so this
should also be useful for other drivers.

Signed-off-by: Steve Glendinning <steve.glendinning@smsc.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Steve Glendinning
2008-12-16 02:00:48 -08:00
committed by David S. Miller
parent e18ce34654
commit bc02ff95fe
5 changed files with 33 additions and 92 deletions

View File

@@ -1227,28 +1227,6 @@ static u16 tg3_advert_flowctrl_1000X(u8 flow_ctrl)
return miireg;
}
static u8 tg3_resolve_flowctrl_1000T(u16 lcladv, u16 rmtadv)
{
u8 cap = 0;
if (lcladv & ADVERTISE_PAUSE_CAP) {
if (lcladv & ADVERTISE_PAUSE_ASYM) {
if (rmtadv & LPA_PAUSE_CAP)
cap = TG3_FLOW_CTRL_TX | TG3_FLOW_CTRL_RX;
else if (rmtadv & LPA_PAUSE_ASYM)
cap = TG3_FLOW_CTRL_RX;
} else {
if (rmtadv & LPA_PAUSE_CAP)
cap = TG3_FLOW_CTRL_TX | TG3_FLOW_CTRL_RX;
}
} else if (lcladv & ADVERTISE_PAUSE_ASYM) {
if ((rmtadv & LPA_PAUSE_CAP) && (rmtadv & LPA_PAUSE_ASYM))
cap = TG3_FLOW_CTRL_TX;
}
return cap;
}
static u8 tg3_resolve_flowctrl_1000X(u16 lcladv, u16 rmtadv)
{
u8 cap = 0;
@@ -1288,7 +1266,7 @@ static void tg3_setup_flow_control(struct tg3 *tp, u32 lcladv, u32 rmtadv)
if (tp->tg3_flags2 & TG3_FLG2_ANY_SERDES)
flowctrl = tg3_resolve_flowctrl_1000X(lcladv, rmtadv);
else
flowctrl = tg3_resolve_flowctrl_1000T(lcladv, rmtadv);
flowctrl = mii_resolve_flowctrl_fdx(lcladv, rmtadv);
} else
flowctrl = tp->link_config.flowctrl;