MIPS: Avoid potential hazard on Context register
set_saved_sp reads Context register. Avoid reading stale value from earlier incomplete write. Issue found and fixed for head.S by Chris Dearman <chris@mips.com>. Signed-off-by: Chris Dearman <chris@mips.com> Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
This commit is contained in:
@ -16,6 +16,7 @@
|
||||
#include <linux/smp.h>
|
||||
#include <linux/slab.h>
|
||||
#include <asm/cacheflush.h>
|
||||
#include <asm/hazards.h>
|
||||
#include <asm/tlbflush.h>
|
||||
#ifdef CONFIG_MIPS_MT_SMTC
|
||||
#include <asm/mipsmtregs.h>
|
||||
@ -36,11 +37,13 @@ extern unsigned long pgd_current[];
|
||||
#ifdef CONFIG_32BIT
|
||||
#define TLBMISS_HANDLER_SETUP() \
|
||||
write_c0_context((unsigned long) smp_processor_id() << 25); \
|
||||
back_to_back_c0_hazard(); \
|
||||
TLBMISS_HANDLER_SETUP_PGD(swapper_pg_dir)
|
||||
#endif
|
||||
#ifdef CONFIG_64BIT
|
||||
#define TLBMISS_HANDLER_SETUP() \
|
||||
write_c0_context((unsigned long) smp_processor_id() << 26); \
|
||||
back_to_back_c0_hazard(); \
|
||||
TLBMISS_HANDLER_SETUP_PGD(swapper_pg_dir)
|
||||
#endif
|
||||
|
||||
|
Reference in New Issue