[SCSI] mpt2sas: Raid 10 Volume is showing as Raid 1E in dmesg
This patch modifies the slave_configure callback so the messages that get sent to system log for RAID1E volumes contain the string "RAID10" instead of "RAID1E". These messages contain information regarding what kind of scsi device is being added. Certain OEMS can enable displaying the RAID10 string instead of RAID1E via manufacturing page 10. The driver will read this config page at driver load time, then determine from the GenericFlags0 bits whether display the RAID10 or RAID1E string, also even drive count is taken into consideration. Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com> Reviewed-by: Eric Moore <Eric.moore@lsi.com> Cc: Stable Tree <stable@kernel.org> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This commit is contained in:
committed by
James Bottomley
parent
34a03bef22
commit
ed79f1280d
@ -1501,7 +1501,13 @@ _scsih_slave_configure(struct scsi_device *sdev)
|
||||
break;
|
||||
case MPI2_RAID_VOL_TYPE_RAID1E:
|
||||
qdepth = MPT2SAS_RAID_QUEUE_DEPTH;
|
||||
r_level = "RAID1E";
|
||||
if (ioc->manu_pg10.OEMIdentifier &&
|
||||
(ioc->manu_pg10.GenericFlags0 &
|
||||
MFG10_GF0_R10_DISPLAY) &&
|
||||
!(raid_device->num_pds % 2))
|
||||
r_level = "RAID10";
|
||||
else
|
||||
r_level = "RAID1E";
|
||||
break;
|
||||
case MPI2_RAID_VOL_TYPE_RAID1:
|
||||
qdepth = MPT2SAS_RAID_QUEUE_DEPTH;
|
||||
|