[PATCH] USB: isp116x-hcd: remove clock() and reset()
This patch removes support for user-provided platform-specific hardware reset and clock starting/stopping functions. Hardware reset was needed earlier as getting the software reset working was tricky due to the lack of documentation. Recently, a number of people using isp116x have said the software reset is working for them. I haven't heard of anybody using the clock starting/stopping. Signed-off-by: Olav Kongas <ok@artecdesign.ee> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
9d233d9fae
commit
f8d23d3098
@@ -19,15 +19,6 @@ struct isp116x_platform_data {
|
||||
prevents stopping internal clock, increasing
|
||||
thereby power consumption in suspended state. */
|
||||
unsigned remote_wakeup_enable:1;
|
||||
/* Hardware reset set/clear. If implemented, this function must:
|
||||
if set == 0, deassert chip's HW reset pin
|
||||
otherwise, assert chip's HW reset pin */
|
||||
void (*reset) (struct device * dev, int set);
|
||||
/* Hardware clock start/stop. If implemented, this function must:
|
||||
if start == 0, stop the external clock
|
||||
otherwise, start the external clock
|
||||
*/
|
||||
void (*clock) (struct device * dev, int start);
|
||||
/* Inter-io delay (ns). The chip is picky about access timings; it
|
||||
expects at least:
|
||||
150ns delay between consecutive accesses to DATA_REG,
|
||||
|
Reference in New Issue