powerpc/windfarm: Fix noisy slots-fan on Xserve (rm31)
slots-fan on G5 Xserve is always running at full speed with windfarm_rm31 driver, resulting in a very high acoustic noise level. It seems the fan parameters are incorrect, and have been copied from the Drive Bay fan (RPM, not present on rm31) of the legacy therm_pm72 driver. This patch changes the parameters to match the Slots fan (PWM) of therm_pm72. With the patch, slots-fan speed drops from 99% to 19% during normal use, and slots-temp settle to ~42'C. Signed-off-by: Aaro Koskinen <aaro.koskinen@iki.fi> CC: <stable@vger.kernel.org> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
This commit is contained in:
committed by
Benjamin Herrenschmidt
parent
3be7db6ab4
commit
fe956a1d40
@@ -439,15 +439,15 @@ static void backside_setup_pid(void)
|
|||||||
|
|
||||||
/* Slots fan */
|
/* Slots fan */
|
||||||
static const struct wf_pid_param slots_param = {
|
static const struct wf_pid_param slots_param = {
|
||||||
.interval = 5,
|
.interval = 1,
|
||||||
.history_len = 2,
|
.history_len = 20,
|
||||||
.gd = 30 << 20,
|
.gd = 0,
|
||||||
.gp = 5 << 20,
|
.gp = 0,
|
||||||
.gr = 0,
|
.gr = 0x00100000,
|
||||||
.itarget = 40 << 16,
|
.itarget = 3200000,
|
||||||
.additive = 1,
|
.additive = 0,
|
||||||
.min = 300,
|
.min = 20,
|
||||||
.max = 4000,
|
.max = 100,
|
||||||
};
|
};
|
||||||
|
|
||||||
static void slots_fan_tick(void)
|
static void slots_fan_tick(void)
|
||||||
|
Reference in New Issue
Block a user